Trident Titan Pro 06M-HB
SKU: TT-AW-0006-HB-01-31-01
Price on request
With its outstandingly high SCOP value, the Trident Titan Pro series offers best-in-class energy efficiency along with stable, reliable heating and cooling performance. The Titan Pro heat pump can reach flow temperatures of up to 75 °C, and the unit delivers full heat pump capacity down to −7 °C.
Key features
Questions about this product?
Get in touch with us.
Specifications
The Trident Titan Pro 06M-HB is a compact, inverter-driven air-to-water heat pump system suitable for heating, cooling and domestic hot water (DHW) production. The HB (Hydro Box) version includes a built-in hydraulic unit, which simplifies system design and offers a transparent, space-saving solution for properties with lower heat demand.
Reliable performance for lower heat demand
The output of the Titan Pro 06M outdoor unit is ideally matched to the heating and cooling needs of smaller and medium-sized, well-insulated modern family homes, terraced houses or holiday homes. The system ensures stable operation even at low outdoor temperatures, while in summer mode its efficient cooling function provides a pleasant indoor climate.
HB (Hydro Box) – integrated hydraulics, simple installation
The HB version includes a separate hydraulic unit that incorporates the most important hydraulic components. This:
- reduces installation time,
- minimises the risk of installation errors,
- provides a clearer plant-room layout,
- makes maintenance and servicing easier.
The Hydro Box is an ideal solution when the system is built with an external DHW tank, a buffer tank or a simpler multi-circuit heating setup.
Energy-efficient, environmentally friendly operation
The inverter technology of the Trident Titan Pro 06M-HB adapts operation to the current heat demand, reducing energy consumption and running costs. The unit uses R290 refrigerant, which ensures a low environmental impact while delivering high efficiency and reliable operation.
Versatile use
With appropriate system design, the Titan Pro 06M-HB is an excellent choice for:
- underfloor heating systems,
- fan coil-based cooling,
- low-temperature radiator heating,
- systems combined with an external DHW tank.
Who is it recommended for?
The Trident Titan Pro 06M-HB is an ideal choice for those who:
- are looking for a heating and cooling solution for a smaller property,
- want a compact heat pump with an integrated hydraulic unit,
- value energy-saving, environmentally friendly technology.
The HB version is especially advantageous when fast installation, a transparent system architecture and reliable long-term operation are key priorities.
Basic data
| Model | Trident Titan Pro 06M - monobloc outdoor unit |
|---|---|
| Article number | TT-SU-0006-MB-01-31-01 |
Key features
| Heat pump energy efficiency class - W35°C / W55°C | A+++ / A+++ |
|---|---|
| SCOP - 35°C / 55°C | 5.18 / 3.91 |
| SEER - 18°C / 7°C | 6.71 / 4.25 |
| Annual energy consumption - heating (35°C/55°C) | 2275 kWh / 2979 kWh |
| Rated heat output (Prated) (35°C/55°C) | 5.70 kW / 5.64 kW |
| Maximum heat output (35°C/55°C) | 6.43 kW / 5.70 kW |
| Seasonal space heating efficiency (ηs) (35°C/55°C) | 204 % / 153 % |
Heat outputs
| Heating capacity A7/W35 (min/max) | 2.10 kW / 6.40 kW |
|---|---|
| Heating capacity A2/W35 (min/max) | 3.04 kW / 6.08 kW |
| Heating capacity A-7/W35 (min/max) | 2.09 kW / 6.15 kW |
| Cooling capacity A35/W18 (min/max) | 3.66 kW / 7.44 kW |
| Cooling capacity A35/W7 (min/max) | 2.47 kW / 5.94 kW |
| Heating capacity (A7/W35) | 6.43 kW |
| Electrical power input (A7/W35) | 1.22 kW |
| COP (A7/W35) | 5.28 |
| Heating capacity (A7/W55) | 5.70 kW |
| Electrical power input (A7/W55) | 1.71 kW |
| COP (A7/W55) | 3.37 |
| Heating capacity (A2/W35) | 6.08 kW |
| Electrical power input (A2/W35) | 1.64 kW |
| COP (A2/W35) | 3.69 |
| Heating capacity (A2/W55) | 5.98 kW |
| Electrical power input (A2/W55) | 2.23 kW |
| COP (A2/W55) | 2.69 |
| Heating capacity (A-7/W35) | 6.15 kW |
| Electrical power input (A-7/W35) | 2.11 kW |
| COP (A-7/W35) | 2.90 |
| Heating capacity (A-7/W55) | 5.22 kW |
| Electrical power input (A-7/W55) | 2.55 kW |
| COP (A-7/W55) | 2.05 |
| Heating capacity (A-15/W35) | 5.71 kW |
| Electrical power input (A-15/W35) | 2.12 kW |
| COP (A-15/W35) | 2.70 |
| Heating capacity (A-15/W55) | 5.01 kW |
| Electrical power input (A-15/W55) | 2.52 kW |
| COP (A-15/W55) | 1.99 |
| Cooling capacity (A35/W18) | 7.44 kW |
| Electrical power input (A35/W18) | 1.83 kW |
| EER (A35/W18) | 4.07 |
| Cooling capacity (A35/W7) | 5.94 kW |
| Electrical power input (A35/W7) | 1.75 kW |
| EER (A35/W7) | 3.39 |
| Max. heating capacity in quiet mode (A-7/W35) | 6.15 kW |
| Max. heating capacity in quiet mode (A-7/W55) | 5.23 kW |
| Max. cooling capacity in quiet mode (A35/W18) | 7.44 kW |
| Max. cooling capacity in quiet mode (A35/W7) | 5.94 kW |
At operating points with an outdoor temperature of 2 °C or below (A2, A-7, A-15), the heating data is given without the defrost cycle included.
Performance data
| Refrigerant | R290 |
|---|---|
| Refrigerant charge | 0.85 kg |
| Compressor type | Twin rotary |
| Compressor manufacturer | GMCC |
| Compressor oil | POE |
Electrical data
| Rated voltage of outdoor unit | 230 V |
|---|---|
| Recommended fuse for outdoor unit | 1 x B 16 A |
Hydraulic data
| Heat exchanger type | Plate heat exchanger |
|---|---|
| Heat exchanger manufacturer | Alfa Laval |
| Water-side pipe connection | G1" male thread |
| Nominal flow rate | 1.03 m³/h |
| Min. / max. flow rate | 0.72 / 1.34 m³/h |
| Internal pressure drop at nominal flow rate | 18 kPa |
| Circulation pump manufacturer | Grundfos |
| Circulation pump type | UPM4XL K 25-90 130 |
Heat source data
| Number of fans | 1 |
|---|---|
| Fan air flow rate | 2850 m³/h |
Operating limits
| Outdoor temperature operating range | −25 / 43 °C |
|---|---|
| Heating water temperature (min/max) | 25 / 75 °C |
| Cooling water temperature (min/max) | 7 / 20 °C |
| Min. / max. operating pressure | 0.8 / 3 bar |
Weight data
| Weight | 100 kg |
|---|
Dimensions
| Width | 1160 mm |
|---|---|
| Depth | 395 mm |
| Height | 740 mm |
Noise level
| Sound power level (EN 12102) | 49 dB(A) |
|---|---|
| Max. sound power level at operating limits | 64 dB(A) |
| Max. sound power level in reduced night mode | 42 dB(A) |